A dynamic walled in area for the decrease of commotion created by pivoting machines.


133 views
Uploaded on:
Description
A dynamic fenced in area for the decrease of commotion delivered by pivoting machines Andrea Vigliotti CIRA Review Depiction of the clamor source The dynamic case Framework portrayal Test set-up Preparatory results Open issues and future work Portrayal of the clamor source
Transcripts
Slide 1

A dynamic nook for the decrease of commotion delivered by pivoting machines Andrea Vigliotti CIRA

Slide 2

Overview Description of the clamor source The dynamic case System depiction Test set-up Preliminary results Open issues and future work

Slide 3

Description of the clamor source Rotating machines, for example, electrical engines, pumps, turbines, compressors, are found in an expansive number of frameworks and speak to frequently a noteworthy wellspring of commotion and aggravation. The decrease of such sources can be gotten by the configuration of particular walled in area yet these arrangements are frequently substantial or inadmissibly overwhelming. On account of the clamor\'s way field delivered by rotational machines great results as far as commotion lessening and softness can be gotten by the utilization of dynamic clamor control methods

Slide 4

Description of the clamor source Rotating machines create verging on intermittent commotion, having a key recurrence and various products of this recurrence

Slide 5

Description of commotion Main trademark are: provincially limited transfer speed a discrete number of frequencies are included and can be independently treated unsurprising turning machines frequently works at settled administrations

Slide 6

The acoustic case A light case with dynamic dividers can be intended to alleviate the unsettling influence delivered by the pivoting unit The points of interest offered for this situation is that it is conceivable to introduce the transducer on the same surface which is transmitting the clamor. Hence it is conceivable to follow up on the source itself.

Slide 7

n 2 n 1 n 3 System depiction A food forward control framework Noise can be encouraged to an advanced sign processor and associated to an accelerometer estimation tackled the unit Advantage is that it is conceivable to sense precisely the aggravating flag and outline a simply sustain forward control framework. DSP PA

Slide 8

a System portrayal in a perfect world: DSP PA H dsp n 1 H 2 y 3 y 2 H 1 y 1 y 4

Slide 9

System depiction Known issues for the general case H 1 and H 2 are hard to acquire in an expository structure H dsp migth not be an easygoing framework In the present application H 1 , H 2 , H dsp require just to be assessed at the frequencies of enthusiasm being the commotion intermittent we can foresee the future

Slide 10

System portrayal Each recurrence segment of the irritating sign can be separately sifted and sent to the actuator and the fenced in area divider, and every walled in area board can be driven exclusively

Slide 11

n 2 n 1 Test set-up Waveform generataor DSP PA dSpace 1104 DSP board Agilent 3230 Waveform generator Nat. Inst. 6535 Daq card Laptop and desktop pcs Microphones Piezoelectric patches Power intensifiers Matlab/simulink Data securing and handling

Slide 12

Test set-up For the testing a dSpace D1104 board has been utilized

Slide 13

Test set-up

Slide 14

Test set-up

Slide 15

Modal portrayal H 1 The recurrence reaction capacities have been tentatively assessed between the amplifier and the receivers and between the actuators and the mouthpieces H 2

Slide 16

Preliminary test outcomes Three cases are viewed as: Purely sinusoidal aggravation Sine clear Minimization of sinusoidal sign at two distinct areas

Slide 17

Preliminary test outcomes Sinusoidal unsettling influence Freq: 334 Hz Attenuation: ~20 dB in sinusoidal excitation great results due to high emanating productivity of the boards things get most noticeably bad in vast transmission capacity excitation due to the uncontrolled conduct around the reverberation

Slide 18

Preliminary test outcomes Same channel with expansive band excitation

Slide 19

Preliminary results Sine clear excitation from 100Hz to 500Hz Up to 25 dB constriction

Slide 20

Preliminary results Filter tuned at 334 Hz and 598Hz

Slide 21

Preliminary results Up to 20 and 10 dB weakening

Slide 22

Preliminary results Exact arrangement may not exist Optimum must be looked and exchange off should be taken DSP PA H DSP PA n 1 H dsp n 1 y 3 y 2 a y 1 y 4

Slide 23

Preliminary results Noise minimized at two areas Up to 15 and 24 dB lessening

Slide 24

Preliminary results Noise minimized at two areas

Slide 25

Open issues and future work Poor boards proficiency as actuator far from its normal frequencies Noise can without much of a stretch be minimized at single focuses troubles emerges when managing huge volumes Phase of exasperating sign basic Stiffer and lighter composite box

Recommended
View more...