CANLYTE Strong STATE LIGHTING.


68 views
Uploaded on:
Category: News / Events
Description
Through each LED for 82W Board Version. Zener Diodes in Parallel to ... Up from the Circuit Board into the Luminaire. Must Quickly & Efficiently Transfer Heat to ...
Transcripts
Slide 1

CANLYTE SOLID STATE LIGHTING Canlyte with Philips, Lightolier SSL, Calculite, Color Kinetics and Keene LED items is situated to be the main organization for SSL items in the Canadian business sector

Slide 2

NextLED Taking LED to the Next Level

Slide 3

NextLED The New Standard in LED Technology Canlyte & Philips LED Development Team Technology High-end Optical Design Standards & Legislation Developed a New Standard in: Light Quality Reliability Energy Efficiency System Approach Develop a Wide Range of Products Commercially Viable & Sustainable Performance

Slide 4

IES Recommended Standards Designed & Tested to IES Recommended Standards IES LM-80 IES Approved Method for Lumen Depreciation Testing of LED Light Sources IES LM-79 IES Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products

Slide 5

NextLED: Luminaires Housing LED Driver Heat Sink LED Circuit Board Asymmetric Collimators Mask

Slide 6

NextLED: Light Engine LED Circuit Board Asymmetric Collimator Orientation Mask

Slide 7

NextLED: Luminaires Optics

Slide 8

NextLED: Optics LEDs Without Optics Have No Light Control

Slide 9

NextLED: Optics Directional Light Control Using Asymmetric Collimators

Slide 10

NextLED: Optics Patented Asymmetrical Collimator Total Internal Reflection (TIR) Optical Principle Medium Beam 66 ° Vertical Aiming Angle Designed Using Optical Simulation Software

Slide 11

NextLED: Optics Refraction edge i < edge r (dependably) i r

Slide 12

NextLED: Optics Refraction edge i < point r (dependably) i r

Slide 13

NextLED: Optics Refraction edge i < edge r (dependably) i r

Slide 14

NextLED: Optics Total Internal Reflection (TIR) edge i = edge r (dependably) r i 100% Internal Reflection (TIR)

Slide 15

NextLED: Optics Total Internal Reflection (TIR)

Slide 16

NextLED Promise: Target Lumens Better Utilization of Lumens on the Task Fewer Initial Lumens Required Puts the Light Where it is Needed Most Achieve the same number of lumens on the assignment with: Lower Energy Use Less Wasted Light Dark Sky Friendly Low Glare Ideal for Preventing Light Trespass

Slide 17

Target Lumens - Garage Premium Metal Halide Spectra-Lyte Source Watts: 150W Input Watts: 185W

Slide 18

Target Lumens - Garage NextLED Spectra-Lyte Source Watts: 82W Input Watts: 95W

Slide 19

Target Lumens - Garage Results 49% Reduction of Input Watts 75% Reduction in Glare Zone Lumens

Slide 20

NextLED: Outdoor Luminaires LED Circuit Board

Slide 21

NextLED: Circuit Board 54 Cree XR-E White Light LEDs 9 Strings of 6 LED in Series 444mA Constant Current Through every LED for 82W Board Version Zener Diodes in Parallel to Each LED End of Life Isolation . Exceptionally Designed Board Tracings for Proper Heat Dissipation Aluminum Backed PCB eGRAF Thermal Interface Material 24 Hour Burn In Period

Slide 22

NextLED: Outdoor Luminaires LED

Slide 23

NextLED: LEDs Cree XR-E White Color Temperature: 5000+K CRI: 72+ Lumens for every LED: 107-114 Forward Voltage: 3.4Vf All LED Products are tried in our Integrating Sphere Cambridge, ON

Slide 24

NextLED: Luminaires Mask

Slide 25

NextLED: Mask Assembly Keyed Orientation

Slide 26

NextLED: Mask Orientation Different Beam Direction Combine to Make a Complete Luminaire Distribution Pre Aimed Light Collimators from the Factory Type Main Beam Left Zone POLE Central/Across Zone Type Main Beam Right Zone

Slide 27

NextLED: Mask Distributions Side Distribution Designed & Tested to IES Recommended Standards LM-79-08: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products Top Distribution Type 2 Type 3 Type 4

Slide 28

NextLED: Luminaires LED Driver

Slide 29

NextLED: Driver Electronic Class II Output 4A Constant Current Versions 120 to 277Vac, 347Vac (Step Down Transformer) 3kV Surge Protection THD < 20% High Level of Voltage Regulation High Power Factor > 0.95 - 30 ° C Start Temperature Built in Thermal Protection

Slide 30

NextLED: Luminaires Heat Sink

Slide 31

NextLED: Heat Transfer LED Sources Conduct Heat Up from the Circuit Board into the Luminaire Must Quickly & Efficiently Transfer Heat to the Outside Environment Heat Sink must not Compromise: The LED Integrity of the Luminaire

Slide 32

NextLED: Heat Transfer Built for the Canadian Environment Downward Heat Sink Design Issues with Upward Facing Heat Sinks Dirt & Debris Build Up Birds Snow & Ice NextLED Conventional LED Downward Heat Sink Upward Heat Sink

Slide 33

NextLED: LEDs Important to Maintain Junction Temperature Lifetime (L 70 ) Based on Junction Temperature IES Standard 60,000 Hour Life @ 70% Lumen Maintenance Designed & Tested to IES Recommended Standards LM-80-08: IESNA Approved Method For Measuring Lumen Depreciation of LED Light Sources

Slide 34

NextLED: Outdoor Luminaires Taking LED to the Next Level

Slide 35

NextLED Spectra-Lyte Available: June 2009

Slide 36

Garage & Canopy NextLED Spectra-Lyte Round & Square 82W NextLED System (95W Input) Distribution: Type II, IV, V (Square & Rectangular) Lumens: 4,900 Lumens Per Watt: 52 Voltages: 120V - 277V & 347V Construction: Die-Cast Aluminum Construction Vandal Resistant Lens Wet Location Listed

Slide 37

NextLED Ellipse & Silhouette Available: June 2009

Slide 38

Architectural Area NextLED Area Light 82W NextLED System (95W Input) Distribution: Type II, III, IV, V Lumens: 4,100 to 4,400 Lumens Per Watt: 43 to 46 Voltages: 120V - 277V & 347V Cutoff: Full & Semi Construction: Die-Cast Aluminum Construction Glass Protective Lens Wet Location Listed

Slide 39

NextLED GeoScapes Available: June 2009

Slide 40

Decorative Wall NextLED GeoScapes Wallcube 82W NextLED System (95W Input) Distribution: Type II, III, IV Lumens: 4,200 Lumens Per Watt: 48 Voltages: 120V - 277V & 347V Cutoff: Full & Semi Construction: Die-Cast Aluminum Construction Glass Protective Lens Wet Location Listed

Slide 41

NextLED FloodPak Available: June 2009

Slide 42

Wall & Security NextLED FloodPak Wallcube 92W NextLED System (95W Input) Distribution: Type II, III, IV Lumens: Up to 4,200 Lumens Per Watt: Up to 48 Voltages: 120V - 277V & 347V Cutoff: Full & Semi Construction: Die-Cast Aluminum Construction Glass Protective Lens Wet Location Listed Not Intended for Flood Applications

Slide 43

Next Generation NextLED Floodlighting PentaFlood Series PF2 & PF3 Available: Q4 2009 Architectural Area Lighting Optra Compact Available: Q4 2009

Slide 44

NextLED Promise Life Cycle Cost Low Total Cost of Ownership LED Technology Typically Cost More Fixture Energy Savings – 30% to half Lower Maintenance Cost Maximum Light Output, Control & Quality Solves Issues of Intensity & Uniformity Patented, Individually Oriented Optics Delivers Target Lumens Reliability Built in State of the Art Clean Room Lachine, Quebec Long Life through Proper Heat Management 24 Hour Burn In 5 Year Warranty

Slide 45

NextLED: Environmentally Friendly Design Night Sky Friendly Fewer Pollutants No Heavy Metals Such as Mercury No Persistent Organic Pollutants (POP) No Volatile Organic Compounds (VOC) RoHS Compliant Parts Restriction of Hazardous Substances Directive Restricts the Use of Six Hazardous Materials Such as: Lead, Mercury, Cadmium

Slide 46

Our LED Promise Low Cost of Ownership Energy Savings High Fixture Efficacy Quality of Light Target Lumens Great Cutoff Uniformity & Consistency Reliability Industry Leading 5 Year Warranty Tested to IES Standards & Testing (LM-79 & LM-80) Long Life (L70)

Slide 47

CANLYTE SOLID STATE LIGHTING Canlyte with Philips, Lightolier SSL, Calculite, Color Kinetics and Keene LED items is situated to be the main organization for SSL items in the Canadian business sector

Recommended
View more...