  1. 9/24/2014 That’s a BIG lens!! Scleral Contact Lenses MOA Convention 10.4.2014 Chris DeRose, OD Average Corneal  diameter = 11.5mm Size matters Average RGP lens = 9.5 mm Soft Contact lens = 14.0 to 14.5mm Mini‐scleral lens = 15.0 to 18.0mm Scleral lens = 18.0 to 24.0mm RGP Soft Contact Lens 1

  2. 9/24/2014 What makes Sclerals different? Scleral Lens Rest on the sclera  (don’t touch the cornea) Vault over the cornea Tear Reservoir between the contact lens and  the eye Insertion and removal process So What? Advantages No corneal touch = no chance of worsening scar  progression Who is a good patient for scleral lenses? Corneal irregularity Corneal scarring or post trauma Keratoconus S/P refractive surgery Advanced dry eye or incomplete lid closure (exposure) S/P Corneal transplant Extreme astigmatism Cosmetic (albinism, trauma, aniridia) No corneal contact and less movement = less  awareness (kinda) Tear reservoir can be therapeutic  Better VA (sometimes dramatic) Easier to compensate for crazy corneal shapes Messed Up Corneas Resurgence Increased O2 permeability of new lens  materials New digital manufacturing processes 2

  3. 9/24/2014 Vault Can we fix this cornea  with scleral lens? Corneal Topography (normal) Corneal Topography (astigmatism) Corneal Topography (Keratoconus) 3

  4. 9/24/2014 Corneal Topography (?) Fitting Must be fit  diagnostically Fitting Alignment with sclera  No bearing on limbus Based on sagittal height Little to no movement Must settle for 30 minutes No conjunctival impingement Spherical over‐refraction Vault Reduction Therapeutic Sclerals Tear Reservoir promotes healing in Ocular  Surface Disease Sjogren’s Stevens Johnson Syndrome Graft vs Host Ocular cicatricial pemphigoid Neurotrophic corneal disease  Exophthalmos Ectropion Eyelid Coloboma Start Steep Minimal Vault Touch 4

  5. 9/24/2014 Insertion and Removal Insertion and Removal Insertion and Removal Insertion and Removal Fill the lens with non‐preserved saline Must break the negative pressure underneath  the lens  Manual method – Using fingers, guide eyelid margin under the bottom  edge of the lens. This will break suction and allow lens  to come out Plunger method – Place the plunger on bottom portion of lens NEVER place the plunger centrally on lens – may result  in corneal damage Place lens on formed  "tripod" (thumb, index, and  middle finger) or use scleral cup Position face parallel to a horizontal plane, typically  the table/mirror and open eyelids wide using  opposite hand.  Insert lens edge into lower cul‐de‐sac while pushing  the lens onto cornea Insertion and Removal Use anesthetic for initial lens dispense Study: Reduces long term drop outs by 75% Patients may be intimidated by size of lens  and handling – Doc presentation is the key 5

  6. 9/24/2014 Complications Complications Contact Lens Optics Complications Sagittal height Increased sagittal height steepens corneal‐lens fit Systemic Conditions that  Affect CLs Cosmetic Sclerals Diabetes Collagen Vascular Disorders Pregnancy Birth Control Thyroid Eye Disease Allergy Anti‐histamine use 6

  7. 9/24/2014 Cosmetic Sclerals Hollywood Sclerals Hollywood Sclerals Why fit scleral lenses? Differentiate your practice Incredibly grateful patients = more referrals Full scope of professional practice More referrals from Ophthalmology/cornea Case Case Patient AW ‐ 55 year old Male  +  Severe Keratoconus OD > OS Has been wearing Rose K lenses OU for many  years Lenses have begun to spontaneously eject VA cCLs: OD 20/40‐ OS 20/40 BVA with specs: 20/400 OD, OS 7

  8. 9/24/2014 Case Case Slit lamp:  Central corneal scarring OD > OS Significant apical thinning OU 2‐3+ central SPK OU Refit to scleral lens – diameter 18.0 mm BVA cCL: OD 20/30 OS 20/30+ 16 hours of comfortable wearing time Refit to SynergEyes Ultrahealth hybrid CL Poor comfort and limited wear time Significant protein build‐up on lenses No corneal contact on central scarring Case References ES, Barr JT, Szczotka‐Flynn LB. Keratoconus. In: Clinical Manual of Contact Lenses. Bennett and Henry, Wolters Kluwer, 4th ed. 2014; Chapter 1: 518–577. DeNaeyerG, Breece R. Fitting techniques for a scleral lens design. Contact Lens Spectrum. 2009; 1:  34–37. DeNaeyerG. Scleral contact lens fitting. Contact Lens Spectrum. 2010; 6: 20–25. DeNaeyerG, Jedlicka J, SchornackMM. Scleral Lenses. In: Clinical Manual of Contact Lenses. Bennett and Henry, Wolters Kluwer, 4th ed. 2014; Chapter 21: 609‐647. Eggink FAGJ, Nuijts RMMA. Revival of the scleral contact lens. Cataract & Refractive Surgery Today  Europe. 2007; 9: 56–7 Jacobs DS. Update on scleral lenses. Current Opinion in Ophthalmology. 2008; 19: 298–301 Kalwerisky K, Davies B, MihoraL, et al. Boston Ocular Surface Prosthesis in the management in  severe periorbital thermal injuries: a case series of 10 patients. Ophthalmology. 2012; 119: 516‐521. 8