Analysis of NGMN Requirements REQ 1 for Quality and Quantity of Alarms

Analysis of NGMN Requirements REQ 1 for Quality and Quantity of Alarms
paly

This slide presents specifications related to 3GPP SA5 specifications for alarm management, including Alarm IRP and AAM IRP. It also discusses the current status of these specifications and their usage by operators for 2G, 3G, and 4G networks.

  • Uploaded on | 0 Views
  • lumi lumi

About Analysis of NGMN Requirements REQ 1 for Quality and Quantity of Alarms

PowerPoint presentation about 'Analysis of NGMN Requirements REQ 1 for Quality and Quantity of Alarms'. This presentation describes the topic on This slide presents specifications related to 3GPP SA5 specifications for alarm management, including Alarm IRP and AAM IRP. It also discusses the current status of these specifications and their usage by operators for 2G, 3G, and 4G networks.. The key topics included in this slideshow are NGMN Requirements, Alarm Management, 3GPP SA5, Alarm IRP, AAM IRP, 2G, 3G, 4G,. Download this presentation absolutely free.

Presentation Transcript


1. 1 Analysis of NGMN Requirements REQ 1: Quality and Quantity of Alarms

2. Slide title :32-35pt Color: R153 G0 B0 Corporate Font : FrutigerNext LT Medium Font to be used by customers and partners : Arial Slide t ext :20-22pt Bullets level 2-5 : 18pt Color:Black Corporate Font : FrutigerNext LT Medium Font to be used by customers and partners : Arial Top right corner for field-mark, customer or partner logotypes. ---------------- The following nine groups of colors are an example of how our design colors can be used, please take note that you should only use one design color group per slide. For specific usage details, refer to the Typesetting Standard. 2 Specifications Related 3GPP SA5 specifications Alarm IRP: TS 32. 111-1, 232.111-2, 32.111-3, 32.111-5, 32.111-7 Advanced Alarm Management (AAM) IRP: 32.12x Current Status of the specifications Specifications have been in place in 3GPP. These have been used by operators for a long time for 2G and 3G and are expected to use it for 4G.

3. Slide title :32-35pt Color: R153 G0 B0 Corporate Font : FrutigerNext LT Medium Font to be used by customers and partners : Arial Slide t ext :20-22pt Bullets level 2-5 : 18pt Color:Black Corporate Font : FrutigerNext LT Medium Font to be used by customers and partners : Arial Top right corner for field-mark, customer or partner logotypes. ---------------- The following nine groups of colors are an example of how our design colors can be used, please take note that you should only use one design color group per slide. For specific usage details, refer to the Typesetting Standard. 3 Quality and Quantity of Alarms Requirements Existing 3GPP Standards Status Overall alarming concept The supplier and their R&D departments are the owner of the detailed system know-how and are responsible for the overall alarming concept. Today the suppliers development departments for network elements and OSS are working often autonomously in that area. The basis to design an overall alarm concept needs to be established between the different vendors product lines before the start of development phase. Concept not a requirement Alarm quantity Only alarms that fulfill the quality requirements and which have an additional benefit to solve abnormal conditions should be forwarded by the NE. Meaningless events must be avoided This should be always the requirement. It is a requirement on the NE and the EMS. Out of Scope of this requirement. Nevertheless on the principle aspect of Alarm Quantity, the 32.12x (AAM IRP) providing some related capabilities on this topic.

4. Slide title :32-35pt Color: R153 G0 B0 Corporate Font : FrutigerNext LT Medium Font to be used by customers and partners : Arial Slide t ext :20-22pt Bullets level 2-5 : 18pt Color:Black Corporate Font : FrutigerNext LT Medium Font to be used by customers and partners : Arial Top right corner for field-mark, customer or partner logotypes. ---------------- The following nine groups of colors are an example of how our design colors can be used, please take note that you should only use one design color group per slide. For specific usage details, refer to the Typesetting Standard. 4 Quality and Quantity of Alarms Requirements Existing 3GPP Standards Status Alarm correlation To fulfill the quality requirements and to reduce the event number correlation must be implemented on all levels (network element & element manager). Correlation rules which cover the whole product including all composed components must be part of the product solution and should not be project specific. FM agents on NE level (e.g. IT-systems) should be used to reduce the number of unwanted events. NE and EMS have to support correlation. Requirement are already defined in the Alarm IRP, but the product may take it as far as they want to. So there may be a need to study and refine this further. Number of alarms In general per incident there should not be more than 10 alarms on the instance which caused the failure. Alarm floods of instances which did not cause the failure need to be blocked in any case. EMSs should have built in control for alarm flood. Iterators can be used to control the alarms sent. In addition AAM IRP may be considered as well.

5. Slide title :32-35pt Color: R153 G0 B0 Corporate Font : FrutigerNext LT Medium Font to be used by customers and partners : Arial Slide t ext :20-22pt Bullets level 2-5 : 18pt Color:Black Corporate Font : FrutigerNext LT Medium Font to be used by customers and partners : Arial Top right corner for field-mark, customer or partner logotypes. ---------------- The following nine groups of colors are an example of how our design colors can be used, please take note that you should only use one design color group per slide. For specific usage details, refer to the Typesetting Standard. 5 Quality and Quantity of Alarms Requirements Existing 3GPP Standards Status Focus on customer and service impact In incident situations the following question need to be answered by the system alarms, without the need for any additional optional tooling: What does this incident mean for the customer and the service at all? Focus on the NE level. Prioritization of alarms Criteria for Critical alarms: Total disturbance of the system or significant service impact for customers Performance, capacity, throughput restrictions Accounting disturbed Criteria for Major alarms: Outage of a redundant component (e.g. outage of a redundant power supply) Introduction of retaliatory actions required, to ensure the service availability Alarm Severity defined in Alarm IRP 32.111-2 follows the ITU-T alarm severity.

6. Slide title :32-35pt Color: R153 G0 B0 Corporate Font : FrutigerNext LT Medium Font to be used by customers and partners : Arial Slide t ext :20-22pt Bullets level 2-5 : 18pt Color:Black Corporate Font : FrutigerNext LT Medium Font to be used by customers and partners : Arial Top right corner for field-mark, customer or partner logotypes. ---------------- The following nine groups of colors are an example of how our design colors can be used, please take note that you should only use one design color group per slide. For specific usage details, refer to the Typesetting Standard. 6 Quality and Quantity of Alarms Requirements Existing 3GPP Standards Status Alarm maintenance manuals Alarm maintenance manuals must contain a clear repair action for the dedicated malfunction. Wherever possible event-based automated repair actions to solve standard error situations without manual interaction should be implemented, if not already implemented on the Network Element level. This is a documentation requirement. The intent here is to add repair action. When the alarm is raised in most cases the repair action may not be known. Additional text, additional info along with help files provide this information. Alarm text Alarm text should contain description of abnormal condition, probable cause, service impact, root cause and a clear short repair action or reference to online maintenance manual. Meaningless events have to be avoided. Additional text, additional info, specific problem, probable cause can be used to determine the root cause of the alarm. Maintenance manual are provided.